| R290 Cuber Ice Machine Values | MC0322AX | MC0322WX | MC0522AX | MC0522WX | MC0722AX | MC0330AX | MC0330WX | MC0530AX | MC0530WX | MC0630AX | MC0630WX | MC0830AX | MC0830WX | MC1030AX | MC1030WX | ||||||||||||||||
| Ice production (lb /24 hr @ 90/70) | 270 lbs | 310 lbs | 350 lbs | 396 lbs | 599 lbs | 290 lbs | 319 lbs | 370 lbs | 388 lbs | 485 lbs | 538 lbs | 762 lbs | 810 lbs | 830 lbs | 910 lbs | ||||||||||||||||
| Ice production (lb /24 hr @ 70/50) | 362 lbs | 422 lbs | 464 lbs | 510 lbs | 734 lbs | 358 lbs | 372 lbs | 470 lbs | 580 lbs | 603 lbs | 915 lbs | 920 lbs | 1019 lbs | 995 lbs | |||||||||||||||||
| Water use, gallons ice only (per 100 gal) | 17 gal | 17.5 gal | 17.5 gal | 17.8 gal | 17.9 gal | 17.9 gal | 17.7 gal | 17.6 gal | 17 gal | 17.8 gal | 16.3 gal | ||||||||||||||||||||
| Ice weight / cycle (lb) | 3 lbs | 3 lbs | 5.3 lbs | 5.3 lbs | 7.3 lbs | 3 lbs | 3.2 lbs | 5.6 lbs | 5.2 lbs | 5 lbs | 5.8 lbs | 7 lbs | 7 lbs | 7.3 lbs | 7.7 lbs | ||||||||||||||||
| Refrigerant charge, oz R290 | 6 oz | 4 oz | 6.5 oz | 5.25 oz | 8.5 oz | 6 oz | 5 oz | 6.5 oz | 5.25 oz | 6.5 oz | 6.5 oz | 14.5 oz | 13.5 oz | 13.5 oz | 11.5 oz | ||||||||||||||||
| Fan pressure cut out / cut in, PSIG | 200/150 psig | 200/150 psig | 200/150 psig | 200/150 psig | 200/150 psig | 200/150 psig | 200/150 psig | 200/150 psig | |||||||||||||||||||||||
| High pressure cut out / cut in, PSIG | 350/250 psig | 350/250 psig | 350/250 psig | 350/250 psig | 350/250 psig | 350/250 psig | 350/250 psig | ||||||||||||||||||||||||
| Cycle Time (minutes) @ 70/50 | 12 min | 9.5 min | 16 min | 15 min | 14 min | 12.5 min | 11 min | 16.5 min | 15 min | 13 min | 12 min | 11.5 min | 11 min | 11 min | 11 min | ||||||||||||||||
| Cycle Time (minutes) @ 90/70 | 16 min� | 14 min | 21 min� | 19 min | 19 min | 15 min | 12.5 min | 22 min | 19 min | 16 min | 15 min | 14 min | 13 min | 13 min | 12.5 min | ||||||||||||||||
| Beginning Freeze - Low Side Pressures @ 70/50 | 30 psi | 38 psi | 38 psi | 36 psi | 36 psi | 30 psi | 35 psi | 25 psi | 36 psi | 34 psi | 25 psi | 32 psi | 32 psi | 29 psi | 28 psi | ||||||||||||||||
| Ending Freeze - Low Side Pressures @ 70/50 | 15 psi | 17 psi | 21 psi | 21 psi | 22 psi | 13 psi | 21 psi | 15 psi | 22 psi | 17 psi | 15 psi | 18 psi | 21 psi | 16 psi | 12 psi | ||||||||||||||||
| Beginning Harvest - Low Side Pressures @ 70/50 | 82 psi | 77 psi | 68 psi | 70 psi | 72 psi | 80 psi | 78 psi | 58 psi | 70 psi | 63 psi | 58� psi | 81 psi | 69 psi | 74 psi | 58 psi | ||||||||||||||||
| Ending Harvest - Low Side Pressures @ 70/50 | 76 psi | 73 psi | 66 psi | 65 psi | 68 psi | 80 psi | 65 psi | 65 psi | 65 psi | 63 psi | 65 psi | 78 psi | 74 psi | 70 psi | 60 psi | ||||||||||||||||
| Average Head pressure. @70/50 | 160 psi | 180 psi | 158 psi | 180 psi | 191 psi | 150 psi | 180 psi | 150 psi | 180 psi | 175 psi | 180 psi | 160 psi | 180 psi | 167 psi | 180 psi | ||||||||||||||||
| Beginning Freeze - Low Side Pressures @ 90/70 | 36 psi | 35 psi | 39 psi | 35 psi | 39 psi | 39 psi | 28 psi | 45 psi | 36 psi | 36 psi | 36 psi | 35 psi | 31 psi | 32 psi | 29 psi | ||||||||||||||||
| Ending Freeze - Low Side Pressures @ 90/70 | 16 psi | 17 psi | 22 psi | 21psi | 24 psi | 14 psi | 13 psi | 20 psi | 21 psi | 18 psi | 14 psi | 19 psi | 17 psi | 16 psi | 16 psi | ||||||||||||||||
| Beginning Harvest - Low Side Pressures @ 90/70 | 88 psi | 91 psi | 78 psi | 72 psi | 77 psi | 78 psi | 85 | 78 psi | 72 psi | 74 psi | 66 psi | 78 psi | 66 psi | 87 psi | 72 psi | ||||||||||||||||
| Ending Harvest - Low Side Pressures @ 90/70 | 85 psi | 85 psi | 72 psi | 68 psi | 76 psi | 85 psi | 85 | 80 psi | 68 psi | 71 psi | 70 psi | 83 psi | 75 psi | 93 psi | 72 psi | ||||||||||||||||
| Average Head pressure. @90/70 | 200 psi | 180 psi | 206 psi | 180 psi | 241 psi | 200 psi | 180 | 185psi | 185 psi | 210 psi | 180 psi | 230 psi | 180 psi | 215 psi | 180 psi | ||||||||||||||||
| Comp suction line temp beffining freeze | 73�F | 57�F | 56�F | 52�F | 60�F | 64�F | 60�F | 60�F | 62�F | 55�F� | 43�F | 48�F | 50�F | 64�F | 46�F | ||||||||||||||||
| Comp suction line temp end of freeze | 55�F | 47�F | 45�F | 50�F | 40�F | 56�F | 50�F | 50�F | 51�F | 44�F� | 28�F | 42�F | 38�F | 54�F | 38�F | ||||||||||||||||
| Evap inlet line temps beginning of freeze | 27�F | 23�F | 20�F | 19�F | 31�F | 20�F | 12�F | 12�F | 30�F | 21�F | 27�F | 20�F | 15�F | 17�F | 14�F | ||||||||||||||||
| Evap inlet line� l temps end of freeze | -6.5�F | -4�F | 0.5�F | 0.5�F | 7.7�F | -10�F | -10�F | 10�F | 7�F | -2�F | -7�F | -.5�F | -4�F | .05�F | -12�F | ||||||||||||||||
| Evap inlet line temp havest� | 83�F | 70�F | 51�F | 56�F | 49�F | 82�F | 83�F | 83�F | 69�F | 80�F | 73�F | 78�F | 68�F | 80�F | 100�F | ||||||||||||||||
| Number of Evaporators | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | ||||||||||||||||
|
R290
Flaker/Nugget Ice Machine Values |
NH0422AX-1 | NS0422AX-1 | FS0522AX-1 | NH0422WX-1 | NS0422WX-1 | FS0522WX-1 | NH0622AX-1 | NS0622AX-1 | FS0822AX-1 | NH0622WX-1 | NS0622WX-1 | FS0822WX-1 | NH0922AX-32 | NS0922AX-32 | FS1222AX-32 | NH0922WX-32 | NS0922WX-32 | FS1222WX-32 | NH0922AX-1 | NS0922AX-1 | NH1322AX-32 | NS1322AX-32 | FS1522AX-32 | NH1322WX-32 | NS1322WX-32 | UN0815AX-1A | UF0915AX-1A | UN1215AX-1A | UF1415AX-1A | UN1520AX-1A | UF2020AX-1A |
| Ice production (lb /24 hr @ 90/70) | 333 lbs | 334 lbs | 381 lbs | 335 lbs | 334 lbs | 384 lbs | 510 lbs | 513 lbs | 597 lbs | 540 lbs | 538 lbs | 621 lbs | 694 lbs | 707 lbs | 827 lbs | 783 lbs | 797 lbs | 898 lbs | 675 lbs | 674 lbs | 1006 lbs | 1021 lbs | 1166 lbs | 1072 lbs | 1142 lbs | 85 lbs | 90 lbs | 115 lbs | 123 lbs | 155 lbs | 169 lbs |
| Ice production (lb /24 hr @ 70/50) | 375 lbs | 422 lbs | 483 lbs |
475
lbs |
475 lbs | 521 lbs | 663 lbs | 676 lbs | 755 lbs | 633 lbs | 645 lbs | 749 lbs | 859 lbs | 884 lbs | 1010 lbs | 926 lbs | 975 lbs | 1039 lbs | 850 lbs | 875 lbs | 1199 lbs | 1314 lbs | 1470 lbs | 1400 lbs | 1484 lbs | 126 lbs | 127 lbs | 164 lbs | 172 lbs | 196 lbs | 218 lbs |
| Water use, gallons ice only (per 100 gal) | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal | < 12 gal |
| Refrigerant charge, oz R-290 | 6 oz | 6 oz | 6 oz | 4.5 oz | 4.5 oz | 4.5 oz | 6.5 oz | 6.5 oz | 6.5 oz | 5.25 oz | 5.25 oz | 5.25 oz | 7 oz | 7 oz | 7 oz | 6 oz | 6 oz | 6 oz | 7 oz | 7 oz | 12 oz | 12 oz | 12 oz | 10 oz | 10 oz | 3 oz | 3 oz | 3.25 oz | 3.25 oz | 3 oz | 3 oz |
| High pressure cut out / cut in, PSIG | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | 250 & 350 psig | n/a | n/a | n/a | n/a | n/a | n/a |
| Low pressure cut out/ cut in. PSIG | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 15 & 30 psig | 10 & 25 psig | 10 & 25 psig | 10 & 25 psig | 10 & 25 psig | 10 & 25 psig | n/a | n/a | n/a | n/a | n/a | n/a |
| Freeze - Low Side Pressures @ 70/50 | 25 psi | 25.2 psi | 24.6 psi | 23 psi | 23 psi | 22.4 psi | 20.2 psi | 19.9 psi | 19.3 psi | 20 psi | 20.1 psi | 19.5 psi | 22.1 psi | 22.1 psi | 21.6 psi | 23.3 psi | 23 psi | 22.4 psi | 20 psi | 20.8 psi | 17.6 psi | 17 psi | 16 psi | 13 psi | 12.5 psi | 32.8 psi | 32.7 psi | 28.3 psi | 28 psi | 24 psi | 23.9 psi |
| Freeze - High Side Pressures @ 70/50 | 143.8 psi | 144.6 psi | 143 psi | 173 psi | 173 psi | 172.2 psi | 160.6 psi | 160.8 psi | 160 psi | 175 psi | 171.8 psi | 177.6 psi | 167.7 psi | 169.1 psi | 168.6 psi | 174.1 psi | 173 psi | 172.2 psi | 165 psi | 166.8 psi | 160.5 psi | 158 psi | 155 psi | 175 psi | 175 psi | 152.9 psi | 165.1 psi | 165.5 psi | 165 psi | 167 psi | 166.9 psi |
| Freeze - Low Side Pressures @ 90/70 | 26.9 psi | 27 psi | 26.6 psi | 26.7 psi | 26.7 psi | 26.6 psi | 22 psi | 21.9 psi | 21.6 psi | 20.9 psi | 20.5 psi | 20.1 psi | 25.2 psi | 25.2 psi | 24.7 psi | 24 psi | 23.5 psi | 23.4 psi | 23 psi | 23.3 psi | 20.1 psi | 19.8 psi | 20 psi | 13 psi | 13.4 psi | 35.6 psi | 34.3 psi | 30.8 psi | 31 psi | 27 psi | 26.7 psi |
| Freeze - High Side Pressures @ 90/70 | 189 psi | 186.5 psi | 188.3 psi | 181 psi | 181 psi | 180.5 psi | 208.9 psi | 210.6 psi | 209.2 psi | 180.4 psi | 182 psi | 183.8 psi | 220.7 psi | 220.3 psi | 219.2 psi | 181.5 psi | 180 psi | 176.6 psi | 215 psi | 214.4 psi | 209.9 psi | 208.2 psi | 209 psi | 180 psi | 180 psi | 199.7 psi | 193.3 psi | 212.5 psi | 212 psi | 221 psi | 221.3 psi |
| Evaporator Height in Inches | 9" | 9" | 9" | 9" | 9" | 9" | 9" | 9" | 9" | 9" | 9" | 9" | 12" | 12" | 12" | 12" | 12" | 12" | 12" | 12" | 12" | 12" | 12" | 12" | 12" | 5" | 5" | 5" | 5" | 5" | 5" |
| Average heat load for air conditioning unit sizing BTUH | 5075 BTUH | 5075 BTUH | 5075 BTUH | 4628 BTUH | 4628 BTUH | 4628 BTUH | 8202 BTUH | 8202 BTUH | 8202 BTUH | 7308 BTUH | 7308 BTUH | 7308 BTUH | 10593 BTUH | 10593 BTUH | 10593 BTUH | 9699 BTUH | 9699 BTUH | 9699 BTUH | 10748 BTUH | 10748 BTUH | 16538 BTUH | 16538 BTUH | 16538 BTUH | 15596 BTUH | 15596 BTUH | 1471 BTUH | 1471 BTUH | 1863 BTUH | 1863 BTUH | 2508 BTUH | 2508 BTUH |
| Water use, water cooled condenser only / 100 lbs ice | n/a | n/a | n/a | 50 gal | 50 gal | 46 gal | n/a | n/a | n/a | 48 gal | 44 gal | 40 gal | n/a | n/a | n/a | 58 gal | 55 gal | 50 gal | n/a | n/a | n/a | n/a | n/a | 35 gal | 30 gal | n/a | n/a | n/a | n/a | n/a | n/a |
| Water Cooled Condenser GPM @ 45�F temp | 0.17 GPM | 0.17 GPM | 0.17 GPM | 0.21 GPM | 0.21 GPM | 0.21 GPM | 0.37 GPM | 0.37 GPM | 0.36 GPM | 0.34 GPM | 0.31 GPM | n/a | n/a | n/a | n/a | n/a | n/a | ||||||||||||||
| Compressor Amps - Single Phase | 6.4A | 6.4A | 6.4A | 6.4A | 6.4A | 6.4A | 8.7A | 8.7A | 8.7A | 8.7A | 8.7A | 8.7A | 6.7A | 6.7A | 6.7A | 6.7A | 6.7A | 6.7A | 13A | 13A | 10A | 10A | 10A | 10A | 10A | 2.15A | 2.15A | 2.73A | 2.73A | 3.7A | 3.7A |
| Superheat (Degrees F.) | 15.6�F | 15.3�F | 15.5�F | 13.7�F | 13.7�F | 13.8�F | 12.7�F | 13.7�F | 13.4�F | 14.4�F | 14.5�F | 14.7�F | 10.3�F | 10.3�F | 10.9�F | 11.7�F | 11�F | 10.7�F | 13�F | 12.6�F | 12.5�F | 8.1�F | 10�F | 12�F | 12�F | 1.3�F | 2.8�F | 1.7�F | 2�F | 2�F | 2�F |
| Auger motor amp draw | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 1.9-2.3A | 0.9-1.2A | 0.9-1.2A | 0.9-1.2A | 0.9-1.2A | 0.9-1.2A | 0.9-1.2A | 1.9-2.3A | 1.9-2.3A | 0.9-1.2A | 0.9-1.2A | 0.9-1.2A | 0.9-1.2A | 0.9-1.2A | 0.75A | 0.75A | 0.75A | 0.75A | 0.75A | 0.75A |
| Metering device� | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | TXV | cap tube | cap tube | cap tube | cap tube | cap tube | cap tube |